Overview
The server is orderable in different versions, each with a different front panel/drive-backplane configuration.
-
Cisco UCS C220 M5 (UCSC-220-M5SX)—Small form-factor (SFF) drives, with 10-drive backplane. Supports up to 10 2.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs.
-
Cisco UCS C220 M5 (UCSC-220-M5SN)—SFF drives, with 10-drive backplane. Supports up to 10 2.5-inch NVMe-only SSDs.
-
Cisco UCS C220 M5 (UCSC-220-M5L)—Large form-factor (LFF) drives, with four-drive backplane. Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter drive sled is required to hold 2.5-inch SSDs.
External Features
This topic shows the external features of the server versions.
Cisco UCS C220 M5 Server (SFF Drives) Front Panel Features
The following figure shows the front panel features of the small form-factor drive versions of the server.
For definitions of LED states, see Front-Panel LEDs.
![Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (1) Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (1)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/305001-306000/305949.jpg)
1 | Drive bays 1 – 10 support SAS/SATA hard disk drives (HDDs) and solid state drives (SSDs) | 7 | Fan status LED |
2 |
| 8 | Network link activity LED |
3 | Power button/power status LED | 9 | Temperature status LED |
4 | Unit identification button/LED | 10 | Pull-out asset tag |
5 | System status LED | 11 | KVM connector (used with KVM cable that provides one DB-15 VGA, one DB-9 serial, and two USB connectors) |
6 | Power supply status LED | - |
Cisco UCS C220 M5 Server (LFF Drives) Front Panel Features
The following figure shows the front panel features of the large form-factor drive version of the server.
For definitions of LED states, see Front-Panel LEDs.
![Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (2) Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (2)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/305001-306000/305950.jpg)
1 | Drive bays 1 – 4 support SAS/SATA HDDs and SSDs | 7 | Temperature status LED |
2 | Drive bays 1 and 2 support NVMe PCIe SSDs. A size-converter drive sled is required if 2.5-inch SSDs are used. | 8 | Power supply status LED |
3 | Power button/power status LED | 9 | Network link activity LED |
4 | Unit identification button/LED | 10 | KVM connector (used with KVM cable that provides one DB-15 VGA, one DB-9 serial, and two USB connectors) |
5 | System health LED | 11 | Pull-out asset tag |
6 | Fan status LED | - |
Cisco UCS C220 M5 Server Rear Panel Features
The rear panel features are the same for all versions of the server.
For definitions of LED states, see Rear-Panel LEDs.
![Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (3) Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (3)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/305001-306000/305951.jpg)
1 | Modular LAN-on-motherboard (mLOM) card bay (x16 PCIe lane) | 7 | Rear unit identification button/LED |
2 | USB 3.0 ports (two) | 8 | Power supplies (two, redundant as 1+1) |
3 | Dual 1-Gb/10-Gb Ethernet ports (LAN1 and LAN2) The dual LAN ports can support 1 Gbps and 10 Gbps, depending on the link partner capability. | 9 | PCIe riser 2/slot 2 (x16 lane) Includes PCIe cable connectors for front-loading NVMe SSDs (x8 lane) |
4 | VGA video port (DB-15 connector) | 10 | PCIe riser 1/slot 1 (x16 lane) |
5 | 1-Gb Ethernet dedicated management port | 11 | Threaded holes for dual-hole grounding lug |
6 | Serial port (RJ-45 connector) | - |
Serviceable Component Locations
This topic shows the locations of the field-replaceable components and service-related items. The view in the following figure shows the server with the top cover removed.
![Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (4) Cisco UCS C220 M5 Server Installation and Service Guide - Overview [Cisco UCS C220 M5 Rack Server] (4)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/305001-306000/305952.jpg)
1 | Front-loading drive bays 1–10 support SAS/SATA drives.
| 10 | Power supplies (hot-swappable when redundant as 1+1) |
2 | Cooling fan modules (seven, hot-swappable) | 11 | Trusted platform module (TPM) socket on motherboard (not visible in this view) |
3 | Supercap unit mounting bracket (RAID backup) | 12 | PCIe riser 2/slot 2 (half-height, x16 lane) Includes PCIe cable connectors for front-loading NVMe SSDs (x8 lane) |
4 | DIMM sockets on motherboard (12 per CPU) | 13 | PCIe riser 1/slot 1 (full-height, x16 lane) Includes socket for Micro-SD card |
5 | CPUs and heatsinks (up to two) | 14 | Modular LOM (mLOM) card bay on chassis floor (x16 PCIe lane), not visible in this view |
6 | Mini-storage module socket. Options:
| 15 | Modular RAID (mRAID) riser, can optionally be a riser that supports either:
|
7 | Chassis intrusion switch (optional) | 16 | PCIe cable connectors for front-loading NVMe SSDs on PCIe riser 2 |
8 | Internal USB 3.0 port on motherboard | 17 | Micro-SD card socket on PCIe riser 1 |
9 | RTC battery, vertical socket | - |
The Technical Specifications Sheets for all versions of this server, which include supported component part numbers, are at Cisco UCS Servers Technical Specifications Sheets (scroll down to Technical Specifications).
Summary of Server Features
The following table lists a summary of server features.
Feature | Description |
---|---|
Chassis | One rack-unit (1RU) chassis |
Central Processor | Up to two CPUs from the Intel Xeon Processor Scalable Family. This includes CPUs from the following series:
|
Memory | 24 DDR4 DIMM sockets on the motherboard (12 each CPU) |
Multi-bit error protection | Multi-bit error protection is supported |
Baseboard management | BMC, running Cisco Integrated Management Controller (Cisco IMC) firmware. Depending on your Cisco IMC settings, Cisco IMC can be accessed through the 1-Gb dedicated management port, the 1-Gb/10-Gb Ethernet LAN ports, or a Cisco virtual interface card. |
Network and management I/O | Rear panel:
Front panel:
|
Modular LOM | One dedicated socket (x16 PCIe lane) that can be used to add an mLOM card for additional rear-panel connectivity. |
Power | Two power supplies, redundant as 1+1:
Do not mix power supply types or wattages in the server. |
ACPI | The advanced configuration and power interface (ACPI) 4.0 standard is supported. |
Cooling | Seven hot-swappable fan modules for front-to-rear cooling. |
PCIe I/O | Two horizontal PCIe expansion slots on a PCIe riser assembly. See PCIe Slot Specifications for specifications of the slots. |
InfiniBand | The PCIe bus slots in this server support the InfiniBand architecture. |
Storage, front-panel | The server is orderable in three different versions, each with a different front panel/drive-backplane configuration.
|
Storage, internal | The server has these internal storage options:
|
Storage management | The server has a dedicated internal mRAID riser that supports one of the following storage-controller options:
For a detailed list of storage controller options, see Supported Storage Controllers and Cables. |
RAID backup | The server has a mounting bracket near the cooling fans for the supercap unit that is used with the Cisco modular RAID controller card. |
Integrated video | Integrated VGA video. |